<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>2000</ErrorNumber>
<ErrorFamily>Non-Volatile Storage</ErrorFamily>
<ErrorMessage>
NVS: checksum error in &lt;NVS subsystem&gt; calibration block
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The calibration parameters saved on the MPE for the specified subsystem are
un-initialized or corrupted. Except when a subsystem has been loaded
successfully from the head, default values have been loaded into all the
subsystem's active calibration parameters.
</text></DescriptionText>
<DescriptionText><text>
Since all subsystems are normally initialized when a recorder is integrated,
this error should not occur during normal operation, except possibly during
firmware upgrades.
</text></DescriptionText>
<DescriptionText><text>
The firmware determines whether a subsystem's parameters are valid or corrupt
with a checksum "hidden" at the end of each subsystem's calibration and
configuration block. A corrupt checksum is corrected when a subsystem is
initialized using "nvs init all|(&lt;subsys&gt; cal|cfg)", or saved using "nvs save
all|(&lt;subsys&gt; [cal|cfg])".
</text></DescriptionText>
<DescriptionText><text>
If firmware has been downloaded recently, this error could be due to an
incomplete upgrade (or downgrade) procedure and can be safely ignored until the
upgrade is complete.  Note that the "nvs upgrade" command should not be used
more than once per upgrade.  Therefore, if you are uncertain whether or not the
upgrade command has been issued since the download, it is safer not to use it.
</text></DescriptionText>
<DescriptionText><text>
If no upgrade is in progress, the cause of the NVS corruption should be
determined. Inspect the "Saved" column of the subsystem's calibration
parameters:
</text></DescriptionText>
<DescriptionText><NumberedList>
<ListItem><Text>If most or all of the saved values are unreasonable, then the subsystem has</Text></ListItem>
likely never been initialized, or it was corrupted by an incomplete firmware
upgrade.  The following procedure should correct the error.
<ListItem><Text>If most or all of the save values appear reasonable, then a more serious cause</Text></ListItem>
is possible and the error message should be reported to the responsible firmware
programmer.  The NVS part on the MPE could be failing, or a firmware bug could
be responsible (Green Platesetter version 1.57 had such a bug).  The following
procedure will correct the error, but it may re-occur.
</NumberedList></DescriptionText>
<DescriptionText><text>
No matter what the cause of this error, and unless the "nvs upgrade" command can
be used safely, the best approach is to restore the subsystem from the most
recent NVS dump file. Find the subsystem and enter the parameter values listed
there.  If the either the "Saved values no different than defaults" or
"Unitialized section, defaults always loaded" message appears under the
subsystem heading, no values need be entered. In all cases, the subsystem can
then be saved with "nvs save &lt;subsys&gt; cal".
</text></DescriptionText>
<DescriptionText><text>
Note that if a large number of "checksum error" message(s) are reported after an
"fload memory" command has been used to restore NVS, the firmware version used
to make the backup file and the current firmware version are possibly
incompatible.  If a more recent backup file is not available (preferably one
made with "nvs dump ..."), the firmware should be downgraded to the version used
to make the backup file.  The firmware can then be upgraded from there following
the appropriate upgrade procedure.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Record error message and contact Creo Service
</text></DescriptionText>
</OperatorAction>
<Cause>
Firmware upgrade (or downgrade) in progress - should be fixed by "nvs upgrade" command
</Cause>
<Cause>
NVS never properly initialized
</Cause>
<Cause>
Version mismatch between current firmware and firmware that created "fload memory" file
</Cause>
<Cause>
NVS corrupted by firmware bug
</Cause>
<Cause>
Faulty NVS part on MPE
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:17 2008 PST
</Updated>
<Links>
</Links>
</Error>